Ask Question
12 December, 14:28

A manufacturer uses statistical process control to control the quality of the firm's products. Samples of 50 of Product A are taken, and a defective/acceptable decision is made on each unit sampled. For Product B, the number of flaws per unit is counted. What type (s) of control charts should be used?

+2
Answers (1)
  1. 12 December, 17:31
    0
    P - Chart for A

    C - Chart for B

    Explanation:

    P - Charts are the statistical tool in the form of charts which describes the share or proportion of non conforming, basically non acceptable units in the selected sample.

    It only has pass/fail, yes/no types of tools to verify and describe the conditions satisfied.

    C - Charts are the statistical tools, that counts the non conforming or non acceptable units, individually. It uses a count type technique. In this case also for Product B the flaws are counted per unit basis.
Know the Answer?
Not Sure About the Answer?
Find an answer to your question ✅ “A manufacturer uses statistical process control to control the quality of the firm's products. Samples of 50 of Product A are taken, and a ...” in 📘 Business if you're in doubt about the correctness of the answers or there's no answer, then try to use the smart search and find answers to the similar questions.