Ask Question
8 August, 20:50

Three bulbs are connected by tubing, and the tubing is evacuated. The volume of the tubing is 47.0 mL. The first bulb has a volume of 30.0 mL and contains 4.49 atm of argon, the second bulb has a volume of 250 mL and contains 2.64 atm of neon, and the third bulb has a volume of 21.0 mL and contains 9.36 atm of hydrogen. If the stopcocks (valves) that isolate all three bulbs are opened, what is the final pressure of the whole system in atm?

+1
Answers (1)
  1. 9 August, 00:36
    0
    The final pressure of the whole system is 2.849 atm

    Explanation:

    According to Boyle's law, for eacht gas applies the following equation:

    PiVi = PfVf or Pf = PiVi/Vf

    with Pi = the initial pressure

    with Vi = the initial volume

    with Pf = the final pressure

    with Vf = the final volume

    The final volume for each gas is (47.0 + 30.0 + 250 + 21.0) mL, which is in total = 348 mL

    2. For the first bulb, with argon:

    Pf = (4.49 atm) (30.0 mL) / (348 mL)

    = 0.387 atm

    For the second bulb, with neon

    Pf = (2.64 atm) (250 mL) / (348 mL)

    = 1.897 atm

    For the third bulb, with hydrogen:

    Pf = (9.36 atm) (21 mL) / (348 mL)

    = 0.565 atm

    Step 3:Calculate the final pressure

    P total = P (Ar) + P (Ne) + P (H2)

    = (0.387 + 1.897 + 0.565) atm

    = 2.849 atm

    The final pressure of the whole system is 2.849 atm
Know the Answer?
Not Sure About the Answer?
Find an answer to your question ✅ “Three bulbs are connected by tubing, and the tubing is evacuated. The volume of the tubing is 47.0 mL. The first bulb has a volume of 30.0 ...” in 📘 Chemistry if you're in doubt about the correctness of the answers or there's no answer, then try to use the smart search and find answers to the similar questions.