Ask Question
28 October, 10:07

The two pond system is fed by a stream with flow rate 1.0 MGD (million gallons per day) and BOD (nonconservative pollutant) concentration of 20 mg/L. The rate of decay of BOD is 0.3/day. The volume of the first pond is 5 million gallons and the second is 3 million. Assuming complete mixing within the pond, find the BOD concentration leaving each pond.

+5
Answers (1)
  1. 28 October, 10:54
    0
    Answer: First pond = 8.0 mg/L

    second pond = 4.2 mg/L

    Explanation:

    Cn/Co = [ 1 / [ 1 + (k*t/n) ]]

    for the first pond

    where Co into the first pond is 20mg/L,

    Cn = 20*[ 1 / [ 1 + ((1 x 5) / 0.3) ]]

    Cn = 8 mg/L

    into the second pond we calculate the BOD leaving the pond of volume 3million liters

    we have Cn = 4.2 mg/L
Know the Answer?
Not Sure About the Answer?
Find an answer to your question ✅ “The two pond system is fed by a stream with flow rate 1.0 MGD (million gallons per day) and BOD (nonconservative pollutant) concentration ...” in 📘 Engineering if you're in doubt about the correctness of the answers or there's no answer, then try to use the smart search and find answers to the similar questions.
Search for Other Answers