The contents of a tank are to be mixed with a turbine impeller that has six flat blades. The diameter of the impeller is 3 m. If the temperature is 20°Cand the impeller is rotated at 30 rpm (rev/min), what will be the power consumption? Use power number (Np) of 3.5

+2
Answers (1)
  1. 16 November, 22:23
    0
    P=3.31 hp (2.47 kW).

    Explanation:

    Solution

    Curve A in Fig1. applies under the conditions of this problem.

    S1 = Da / Dt; S2 = E / Dt; S3 = L / Da; S4 = W / Da; S5 = J / Dt and S6 = H / Dt

    The above notations are with reference to the diagram below against the dimensions noted. The notations are valid for other examples following also.

    32.2

    Fig. 32.2 Dimension of turbine agitator

    The Reynolds number is calculated. The quantities for substitution are, in consistent units,

    D a = 2⋅ft

    n = 90 / 60 = 1.5 r/s

    μ = 12 x 6.72 x 10-4 = 8.06 x 10-3 lb/ft-s

    ρ = 93.5 lb/ft3 g = 32.17 ft/s2

    NRc = ((D a) 2 n ρ) / μ = 2 2 * 1.5*93.5 8.06 * 10 - 3 = 69,600

    From curve A (Fig. 1), for NRc = 69,600, N P = 5.8, and from Eq. P = N P * (n) 3 * (D a) 5 * ρ g c

    The power P = 5.8*93.5 * (1.5) 3 * (2) 5 / 32.17 = 1821⋅ft-lb f/s requirement is 1821/550 = 3.31 hp (2.47 kW).
Know the Answer?
Not Sure About the Answer?
Find an answer to your question ✅ “The contents of a tank are to be mixed with a turbine impeller that has six flat blades. The diameter of the impeller is 3 m. If the ...” in 📘 Engineering if you're in doubt about the correctness of the answers or there's no answer, then try to use the smart search and find answers to the similar questions.