Ask Question
11 November, 08:15

Which of these statements about inducing current in AC and DC motors are true? 1. In an AC induction motor current in the stator is conducted from an external line voltage 2. In an AC induction motor current in the rotor is conducted from an external line voltage 3. In a DC motor current in the armature is conducted from an external line voltage 4. In a DC motor current in the field windings is conducted from an external line voltage

+5
Answers (1)
  1. 11 November, 11:43
    0
    Option 2.

    Explanation:

    In an induction motor the flow of current in the rotor is not conducted by any DC source but by AC source through an external line voltage.

    This happens because in an induction motor the 3 phase supply is given to the stator and the rotor is connected to DC source and as the result of the armature reaction, i. e., when the rotor magnetic field caused by rotor conductor cuts the stator magnetic field, a current is induced in the rotor.

    Thus the conduction of current in the rotor is the result of an external line voltage.
Know the Answer?
Not Sure About the Answer?
Find an answer to your question ✅ “Which of these statements about inducing current in AC and DC motors are true? 1. In an AC induction motor current in the stator is ...” in 📘 Engineering if you're in doubt about the correctness of the answers or there's no answer, then try to use the smart search and find answers to the similar questions.