Ask Question
15 October, 11:44

Saturated steam coming off the turbine of a steam power plant at 40°C condenses on the outside of a 3-cm-outer-diameter, 35-m-long tube at a rate of 140 kg/h.

Determine the rate of heat transfer from the steam to the cooling water flowing through the pipe.

+2
Answers (1)
  1. 15 October, 12:23
    0
    93.57 KJ/s

    Explanation:

    Rate of heat transfer from the steam to the cooling water = mass rate * Heat of vaporization of water at 40 °C

    H vaporization of water 40 °C at saturation pressure = 2406.0 kJ / Kg

    rate of heat transfer = 2406.0 kJ / Kg * 140 Kg / (60 * 60s) = 93.57 KJ/s
Know the Answer?
Not Sure About the Answer?
Find an answer to your question ✅ “Saturated steam coming off the turbine of a steam power plant at 40°C condenses on the outside of a 3-cm-outer-diameter, 35-m-long tube at ...” in 📘 Engineering if you're in doubt about the correctness of the answers or there's no answer, then try to use the smart search and find answers to the similar questions.