1 September, 23:12

A rapid sand filter has a loading rate of 8.00 m/h, surface dimensions of 10 m ' 8 m, an effective filtration rate of 7.70 m/h. A complete filter cycle duration is 52 h and the filter is rinsed for 20 minutes at the start of each cycle. a. What flow rate (m3 / s) does the filter handle during production? b. What volume of water is used for backwashing plus rinsing the filter in each filter cycle?

+2
Answers (1)
  1. 2 September, 00:16
    0
    given data

    loading rate = 8.00 m/h

    filtration rate = 7.70 m/h

    dimensions = 10 m * 8 m

    filter cycle duration = 52 h

    time = 20 min

    to find out

    flow rate and volume of water is used for back washing plus rinsing the filter

    solution

    we consider here production efficiency is 96%

    so here flow rate will be

    flow rate = area * rate of filtration

    flow rate = 10 * 8 * 7.7

    flow rate = 616 m³/h

    and

    we know back washing generally 3 to 5 % of total volume of water per cycle so

    volume of water is = 616 * 52

    volume of water is 32032 m³

    and

    volume of water of back washing is = 4% of 32032

    volume of water of back washing is 1281.2 m³
Know the Answer?
Not Sure About the Answer?
Find an answer to your question ✅ “A rapid sand filter has a loading rate of 8.00 m/h, surface dimensions of 10 m ' 8 m, an effective filtration rate of 7.70 m/h. A complete ...” in 📘 Engineering if you're in doubt about the correctness of the answers or there's no answer, then try to use the smart search and find answers to the similar questions.