Ask Question
27 August, 17:01

A standard cylinder of oxygen used in a hospital has gauge pressure = 2000 psi (13,800 kPa) and volume = 14 L (0.014 m3) at T = 295 K. How long will the cylinder last if the flow rate, measured at atmospheric pressure, is constant at 2.1 L/min?

+2
Answers (1)
  1. 27 August, 20:16
    0
    901.52 minutes

    Step-by-step explanation:

    To do this, we need to assume that the temperature is constant in all the process here. If this is true, then we can also assume that this is a case of an isothermal expansion, therefore, the expression to use is the following:

    P1V1 = P2V2

    Let P2 the atmospherical pressure, and V2 would be the remaining volume of the oxygen. The atmospherical pressure reported is 1 atm or 101.3 kPa

    Solving for V2 in this expression we have the following:

    13,800 * 14 / 101.3 = 1907.21 L

    As this is a low pressure gas, part of it's volume will remain in the cylinder, so, we have to substract these 14 L to V2 to get the real volume of the remaining gas:

    1907.21 - 14 = 1893.21 L

    And we have now the flux which is 2.1 L/min, so:

    t = V/F

    t = 1893.21 / 2.1

    t = 901.52 min.
Know the Answer?
Not Sure About the Answer?
Find an answer to your question ✅ “A standard cylinder of oxygen used in a hospital has gauge pressure = 2000 psi (13,800 kPa) and volume = 14 L (0.014 m3) at T = 295 K. How ...” in 📘 Mathematics if you're in doubt about the correctness of the answers or there's no answer, then try to use the smart search and find answers to the similar questions.